Fixed, automatically activated misting system
This curtain spray system that we installed on a rotary screen for the compost industry has special and very customised features.
During our inspection we found several dust emission problems. During the loading of the feed hopper, the shovel was releasing material, raising a cloud of dust that was dispersing around the site.
Furthermore, once the material was screened and discharged into the bays below, the mechanical shovels, which were in charge of picking up the resulting product, would generate new dust.
That is why we designed a system that acted on both zones independently at the same time.
On the hopper, we have installed a spray line with a presence detector activation system, so that it can only be activated when needed, i.e. when the loader is present.
A second 'L'-shaped spray line was then constructed to cover the area of the heaps produced by the screen, creating a barrier to obstruct the dust caused by the movement of the material by shovels.